H3C Technologies H3C S10500 Series Switches User Manual
Page 34

27
Process ID: 0
Tunnel interface: Tunnel1
VLAN ID: 100
MAC address: 0002-0100-0001
MAC address: 0002-0100-0002
MAC address: 0002-0100-0003
# Verify that Switch B does not have remote addresses in VLAN 100 because VLAN 100 does not
match the routing policy on Switch A. (Details not shown.)
3.
Verify the configuration on Switch C:
# Display information about the EVI tunnel interface.
[SwitchC] display interface tunnel 1
Tunnel1
Current state: UP
Line protocol state: UP
Description: Tunnel1 Interface
Bandwidth: 64kbps
Maximum Transmit Unit: 64000
Internet protocol processing: disabled
Tunnel source 1.1.3.1
Tunnel keepalive enabled, Period(20 s), Retries(2)
Network ID 1
Tunnel protocol/transport GRE_EVI/IP
Output queue - Urgent queuing: Size/Length/Discards 0/100/0
Output queue - Protocol queuing: Size/Length/Discards 0/500/0
Output queue - FIFO queuing: Size/Length/Discards 0/75/0
Last clearing of counters: Never
Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec
Input: 0 packets, 0 bytes, 0 drops
Output: 0 packets, 0 bytes, 0 drops
# Display information about EVI-Link interfaces on Switch C.
[SwitchC] display evi link interface tunnel 1
Interface Status Source Destination
EVI-Link0 UP 1.1.3.1 1.1.1.1
EVI-Link1 UP 1.1.3.1 1.1.2.1
# Display ENDC information.
[SwitchC] display evi neighbor-discovery client summary
Status: I-Init E-Establish P-Probe
Interface Local Address Server Address Network ID Reg Auth Status
Tunnel1 1.1.3.1 1.1.1.1 1 15 disabled E
# Display neighbor entries that Switch C has learned.
[SwitchC] display evi neighbor-discovery client member
Interface: Tunnel1 Network ID: 1
Local Address: 1.1.3.1
Server Address: 1.1.1.1
Neighbor System ID Created Time Expire Status
1.1.1.1 000F-0001-0001 2013/01/01 12:12:12 13 Up