beautypg.com

Vhm/kvs2, And vhm/kv2, Mp e e – Eneo VHM/KV2 User Manual

Page 9

background image

4. Assembly and connection of the cable connection terminal VHM/KV1

(Art. No. 79609)

, VHM/KVS2

(Art. No. 79612)

and VHM/KV2

(Art. No. 79627)

M

Install vertically in the middle section

M of the housing.

P, e

The cable connection terminal circuit board

P is screwed to the studs using the

enclosed self-tapping screws

e (including washers) as shown in the diagram.

Instructions When wiring ensure that the power lines L1 and N are attached to the terminals

provided for them. The earthed wires are supported on the terminals.

Instructions When connecting and operating the heater and camera, ensure that the operating

voltages are the same and the power consumption is permissible.

The heater’s starting current may be more than 10 times the nominal current.

PE
L1
N
PE
N

L1
ST

AT

MAINS

PE

11

10

1

2

3

4

5

6

7

8

9

M

P

e

e

This manual is related to the following products: