Archgard 60-1600I User Manual
Page 14

Chalet 1600I
14
To install or remove the fan module:
1) Remove fan assembly from packaging and inspect to ensure no damage has occurred inside the package.
Please report any damage immediately to your Authorized Archgard Dealer.
2) Align fan assembly with the clips at the bottom of the ash lip. Slide assembly into position. Install four screws at
each side to mount fan assembly as shown.
3) Making sure that wires cords are not caught or pinched into the fan or housing.
Call your dealer if you require assistance. CAUTION: The connection cord should not be routed under or in
front of the assembly and also kept away from any hot surfaces. Do not route cord under or in front of unit.
FAN OPERATION
The CHALET 1600I WOOD Fireplace Insert must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA
C22.1.
FAN WIRING
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors can
cause improper and dangerous operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-pronged
(grounding) plug for your protection against shock haz-
ard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
Electrical Rating = 115/120V ~ 60 Hz 55W
Fan Output Rating = 136 c.f.m.
LINE
GROUND
NEUTRAL
TO APPLIANCE
SPEED CONTROL
110
v
F (43
v
C)
THERMAL SNAP SWITCH
CONVECTION FAN