Dvie22 – Archgard 27-DVIE22N User Manual
Page 19
27-DVIE22
19
SURROUND INSTALLATION
Surround options available are dependent upon the control panel configuration. (See Control Panel Locations
regarding configuration.) Shallow surround options are not available on a unit with ‘Controls Out’ configuration.
Make sure the gas and electrical lines are properly connected to the appliance. Slide the unit into the fireplace
and slide the excess flue liner material back onto the chimney. Before the appliance is fully recessed into the
fireplace, attach the surround onto the appliance.
Attach the surround to the appliance at the locations shown by lining up the tabs on the surround with the slots
on the unit. Make sure the surround drops down and fully engages. Then finish with the wiring connection to
the on/off switch on the side of the trim. Now fully “seat” the unit into its final position.
Care must be taken that Trim Panels or Surrounds shall not seal ventilation openings in the fireplace.
Surround
Mounting tabs
Fig. 19-B
Fig. 19-A
Surround Mounting
A T T E N T I O N
Main On/Off switch must be connected to the surround switch
and in the “on” position for the remote to operate the fireplace
Shown with 27-SKSBS Trim
Fig. 19-C