Removal and fitting of the swivel joint – Aqua Lung Apeks Regulator User Manual
Page 40
US
40
REMOVAL AND FITTING OF
THE SWIVEL JOINT
(1) Remove the swivel assembly
from the second stage body using
an11/16” open ended spanner.
(2) The swivel connector can be
removed from the ball joint while
cleaning.
(3) Refit the hose and tighten the ball nut on to the second stageusing 11/16”
spanner to hold the heat exchanger. Tighten if possible, using an 11/16” crowfoot
torque wrench to 5Nm.
WARNING: It is
important to ensure
that the connector
is re-fitted on re-
connecting the hose
to the second stage.
WARNING: It is
important to ensure
that the hose is
tightened while holding
the heat exchanger. If
not done the spindle
may turn in the
regulator case, causing
serious malfunction.
Regulator Owner’s Manual
............................................................................................