• Water in crankcase

High humidity

Change oil more frequently

Worn seals

Change the oil seals

• Noisy operation

Worn bearings

Change the bearings

Air mixed with water

Check inlet lines for restrictions

and / or proper sizing

• Rough / pulsating, operating with pressure drop

Inlet restriction

Check system for stoppages, air leaks,

correctly sized inlet plumbing to pump

Unloader

Check unloader for proper operation

Air mix in water

Check inlet lines for restrictions and or

proper sizing

• High crankcase temperatures

Wrong grade of oil

Use recommended oil

Improper amount of

oil in crankcase

Adjust oil to proper amount