beautypg.com

Owner’s manual, Trouble shooting – All Power APW5118 User Manual

Page 15

background image

14

Owner’s Manual

Trouble Shooting

• Engine wil not start or stops while operating.

Low-oil shutdown:

Fill engine with oil

Engine switch not in “ON” position:

Turn switch “ON”S

Pressure built up in hose:

Squeeze trigger while starting

• Engine is overloaded

Nozzle partially blocked

Clean Nozzle

Excessive pressure

Shorten the spring coil on the reflux valve

• Pressure increases when gun is locked

Bypass valve blocking

Clean the bypass valve

• Engine is running but pump won’t build maximum pressure or has irregular pressure

Faucet closed

Open faucet

Unit has been stored in freezing temp. Thaw out unit completely

Inadequate water supply

Provide a minimum of 4 GPM at 20 PSI

Water inlet screen clogged

Clean screen

Kink in garden hose

Straighten garden hose

Wand nozzle worn or damaged

Replace nozzle

Air in pump

Run with gun open & wand removed

until steady stream of water is released

Adjustable pressure knob not set

Set to maximum position

to maximum position

Suction or discharge valves clogged

Clean the suction or discharge valves

or worn out

Bypass valve not operating effectively Clean the bypass valve

• No intake of chemicals

Injection tube not securely inserted

Push firmly into injector

into unit

Tube cracked or split

Replace tube

Wrong nozzle

Switch to low pressure nozzle

Injector turned off

Turn collar counter

• Trigger will not move

Gun safety lock engaged

Release safety lock



This manual is related to the following products: