Local operation, cont’d 1, . sec pri – Extron electronic MKP 2000 User Manual
Page 17
MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
Local Operation, cont’d
1
9
2
1
6
8
.
2
5
4
2
5
3
.
.
2
5
5
2
5
5
.
0
0
0
0
0
0
.
.
0
0
0
0
0
0
.
0
0
0
0
0
0
.
.
0
0
0
0
0
0
.
.
.
.
.
.
.
.
.
.
.
.
.
0
0
0
0
0
0
.
.
SEC
Pri
INPUT
OUTPUT
TAKE
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
INPUT
INPUT
INPUT
INPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
Sim
u
ltaneo
u
sly press and hold
the
bu
ttons for 2 seconds.
Release the
bu
ttons.
The LED display sho
w
s the
most-significant octet of the
MKP 2000’s IP address.
Press the O
u
tp
u
t
bu
tton to cycle thro
u
gh
the displayed and edita
b
le octets.
Press the Inp
u
t
bu
tton to cycle thro
u
gh the displa
y
ed and
edita
b
le addresses and to reach the MKP set-
u
p settings
.
Most-significant Octet
(no dot)
Connected to
S
w
itcher
Control Tho
u
gh
Primary (RS-232)
Least-significant Octet
(dot in right-most position)
OP
n
PAS
OUTPUT
OUTPUT
No
Pass-thro
u
gh
Port
Pass-thro
u
gh
MKP 2000’s
IP Address
MKP 2000’s
S
ub
net Mask
MKP 2000’s
Gate
w
ay
Address
Matrix
S
w
itcher’s
IP Address
Connection
Priority
Host Control
Setting
Figure 3-2 — Selecting octet fields and host control
3-6
3-7
2
.
Use the Input button and Output button to select and
display the desired address and octet.
3
.
Press the Cancel button to clear the octet to 000.
4
.
Use the 0 through 9 buttons to enter the desired value for
the octet.
5
.
Repeat steps 2 through 4 to select and change other
addresses and/or octets.
6
.
Use the Input button to select the host control setting
display.
7
.
If necessary, use the Output button to toggle the setting
between pass-through and no pass-through.
8
.
Use the Input button to select the connection priority
display.
9
.
If necessary, use the Output button to toggle the setting
between primary and secondary.
10
.
When all addresses and octets and the host control and
priority settings are correct, press the Take button.
Host control port setting and pass-through communications
When the MKP is:
•
Connected to a computer or control system via its Host
RS-232 port and
•
Is in pass-through mode,
The MKP redirects valid matrix switcher SIS commands that it
receives on its Host RS-232 port to its Switcher RS-232 port.
When the MKP is:
•
Connected to a computer or control system via its Host
RS-232 port and
•
Is in no pass-through mode,
The MKP acts on all valid MKP commands received. It does not
pass the command to its Switcher RS-232 port.
When the MKP is:
•
Selected as primary, it directly controls the matrix
switcher via its Switch RS-232 port or LAN port
•
Selected as secondary,
The MKP controls the matrix switcher through connection to the
primary MKP’s IP address