4-4 Making an Emergency Stop
Use the following procedure shut down the machine in case of an emergency:
1. Press the “Stop” button. This shuts off the rotor drive motor.
2. For emergency machine stops, feedstock must be cleaned out of the hopper and
cutting chamber prior to restarting the machine.
4-5 Shutting Down the Granulator
Use the following procedure to properly and safely shut down the machine:
1. Stop all feeding of material.
2. Allow the granulator to run until the cutting chamber is completely empty.
3. Press the “Off” button. This shuts off the rotor drive motor. The yellow warning light
lights up, and the rotor stops turning.
4. Turn the main power switch to the “off” position. The yellow warning light turns off.
4 Inch Granulator
Chapter 4: Operation
17 of 47