1 –Pump 1-Station Controller
Chapter 7: Appendix
27 of 30
Figure 7: Typical Single-Station Electrical Schematic with Optional Material Receiver Selector
Switch Circuit
18 ga
red (typical)
4
4
1FU
1A
3
1S
1
L1
115 VAC
2
L2
GRD
2
18 ga
white (typical)
2
Power On
G
1CNTL
2
2
2
2
2
2
2
2
Control board
Pump high
vacuum switch
Filter chamber
blowback solenoid
(or pump)
Vacuum
control
panel
Vacuum pump
motor starter
Vacuum pump
vacuum/vent
(or vacuum)
solenoid
Pump shutdown
timer (OFF-DELAY)
(0-30 sec.)
Bin Full
control relay
2CR
13
1DISC-2
1M
10L
1DISC-3
1SOL
11
12
.5 MF SUP
1TMR
12
5
2 3
13
4
4
4
4
4
4
12
1CR
1 2
1TMR
9
8
N. O.
11
8
9
1CR
8
3
4
9
7
1
4
5
2
3
10
6
8
8V
MOV
2SOL
1DISC-4
8
18 ga
blue
15
14
15 2CR 7
1VS
N. O.
1DISC-1
Material
receiver
N. O.
1LS
13
N. O.
2LS
13
N. O.
3LS
13
N. O.
4LS
13
N. O.
5LS
13
N. O.
6LS
13
N. O.
7LS
13
N. O.
8LS
13
N. O.
9LS
13
N. O.
10LS
13
26
25
24
23
22
21
20
19
18
17
1SS
1
2
3
4
5
6
7
8
9
10
12