beautypg.com

Hardware manual – ACTi I51 User Manual

Page 13

background image

www.acti.com


Hardware Manual

13

To connect output devices (DO), map the pins to one of the pin combinations below:

Device

Pin

Mapping Instructions

Digital Output 1

(DO1)

2

12V

Connect the wires of the first output device to

12V

(Pin 2) and

DO1

(Pin 4).

4

DO1

Digital Output 2

(DO2)

6

12V

Connect the wires of the second output device to

12V

(Pin 6) and

DO2

(Pin 8).

8

DO2

The table below shows the DI/DO connection specifications:

Device

DI

Connection design

TTL - compatible logic levels

Voltage

To trigger (low)

Logic level 0: 0V ~ 0.4V

Normal (high)

Logic level 1: 3.1V ~ 30V

Current

10mA ~ 100mA

DO

Connection design

Transistor (Open Collector)

Voltage & Current

< 24V DC, < 50mA

Typical Connection

Based on these specifications, if the DI device has a voltage of 0V ~ 30V or the DO device has

a voltage of < 24V (<50mA), then the camera can supply internal power to these devices and

there is no need to connect the DI/DO device to an external power source.

In this case, wire connection to Pins 1 to 4. Use the

GND

and

DI1

pins to connect a DI device

and use the

12V

and

DO1

pins to connect a DO device. See wiring scheme below:

Consequently, to connect a second DI or DO device, wire the connection to Pins 5 to 8.