„ Improper Network Topologies

It is important to make sure that users have a valid network topology. Common

topology faults include excessive cable length and too many repeaters (hubs)

between end nodes. In addition, the user should make sure that the network

topology contains no data path loops. Between any two ends nodes, there should

be only one active cabling path at any time. Data path loops will cause broadcast

storms that will severely impact the network performance.

Diagnosing LED Indicators

To assist in identifying problems, the switch can be easily monitored through

panel indicators, which describe common problems the user may encounter and

where the user can find possible solutions.

If the power indicator does turn on when the power cord is plugged in, the user

may have a problem with power outlet, or power cord. However, if the switch

powers off after running for a while check for loose power connections, power

losses or surges at power outlet. If the problem still cannot be resolved, please

contact the local dealer for assistance.

„ Cabling

RJ-45 ports: Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP)

cable for RJ-45 connections: 100 Ω Category 3, 4 or 5 cable for 10Mbps

connections or 100Ω Category 5 cable for 100Mbps connections. Also be sure

that the length of any twisted-pair connection does not exceed 100 meters (328

feet). Gigabit port should use Cat-5 or cat-5e cable for 1000Mbps connections.

The length does not exceed 100 meters.