beautypg.com

Edimax Technology Edimax 24 10/100TX + 2 10/100/1000T/Mini-GBIC Combo Web Smart Switch ES-5226RS User Manual

Page 20

background image

14

System IP Configuration

User can configure the IP Settings and DHCP client function in here.

„ IP Address: Manually assign the IP address that the network is using. If

DHCP function is enabled, the user doesn’t need to assign the IP address.

And, the network DHCP server will assign the IP address displaying in this

column for the switch. The default IP is 192.168.2.1.

„ Subnet Mask: Assign the subnet mask to the IP address. If DHCP function is

enabled, and then the user does not need to assign the subnet mask.

„ Gateway: Assign the network gateway for the industrial switch. The default

gateway is 192.168.2.254.

„ IP Configure: Select the IP addressing mode—Static or DHCP. With Static

mode, the user has to fill in IP address, Subnet Mask and Gateway in the

fields respectively. When the radio button of DHCP is selected, the switch will

be assigned an IP address from the network DHCP server. The default IP

address will be replaced by the assigned IP address on DHCP server.

„ Click the Update button to apply the setting.

System IP Configuration interface