6650-2260
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Test
Description
Level
ESD
EN 61000-4-2
Enclosure contact
± 4 kV
Enclosure air
± 8 kV
RF field AM modulated IEC 61000-4-3
Enclosure
10 V/m 80% AM (1 kHz), 80 – 1 000 MHz
Fast transient
EN 61000-4-4
Signal ports
± 1 kV
Power ports
± 2 kV
Surge
Signal ports balanced
± 1 kV line to earth, ± 1 kV line to line
Power ports
± 0.5 kV line to earth, ± 0.5 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency
magnetic field
EN 61000-4-8
Enclosure
100 A/m, 50 Hz, 16.7 Hz & 0 Hz
Pulse Magnetic field
EN 61000-4-9
Enclosure
300 A/m, 6.4 / 16 μs pulse
Voltage dips and
interruption
EN 61000-4-11
AC power ports
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
Mains freq. 50 Hz
EN 61000-4-16
Signal ports
100 V 50 Hz line to earth
Mains freq. 50 Hz
SS 436 15 03
Signal ports
250 V 50 Hz line to line
Voltage dips
and interruption
EN 61000-4-29
DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class B
FCC part 15
Class A
Conducted emission
EN 55022
AC power ports
Class B
FCC part 15
AC power ports
Class B
EN 55022
DC power ports
Class A
Dielectric strength
EN 60950
Signal port to all other
isolated ports
1.5 kVrms 50 Hz 1min
Power port to other
isolated ports
2 kVrms 50 Hz 1min
Environmental
Temperature
Operating
–40 to +70ºC LRW-102PP
–40 to +60ºC LRW-102
Storage & Transport
–40 to +70°C
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 years
Vibration
IEC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
Shock
IEC 60068-2-27
Operating
15 g, 11 ms
Packaging
Enclosure
UL 94
PC / ABS
Flammability class V-1
Dimension W x H x D
35 x 121 x 119 mm
Weight
0.26 kg
Degree of protection
IEC 529
Enclosure
IP 21
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail