Leds for indication on ld-64, Specifications ld-64 – Westermo LD-64 User Manual
Page 12
12
6073-2002
LEDs for indication on LD-64
• PWR: Indicates that the converter has power.
• TD: Indicates that the converter is receiving data on RS-232/V.24, RS-485 side.
• RD:
Indicates that the converter is sending data on RS-232/V.24, RS-485 side.
• Rx1: Indicates received data on fiber channel 1.
• Rx2: Indicates received data on fiber channel 2.
• Tx1: Indicates that the converter is sending data on fiber channel 1 from RS-232/V.24, RS-485 side.
• Tx2: Indicates that the converter is sending data on fiber channel 2 from RS-232/V.24, RS-485 side.
Specifications LD-64
Transmission
Asynchronous
*
, half duplex or simplex
Interface 1
EIA RS-232/ITU-T V.24
9-position screw block
EIA RS-422/RS-485/ITU-T V.11
5-position screw block
Interface 2
4 ST-connectors, see table of power budget
Data rate
2 400 bit/s – 115.2 kbit/s (RS-232-C) 2 400 bit/s – 375 kbit/s
(RS-422/485)
Indicators
Power, TD, RD, TX1, TX2, RX1, RX2
Temperature range
5–50°C, ambient temperature
Humidity
0–95% RH without condensation
Dimension
55x100x128 mm (WxHxD)
Weight
0.6 kg AC / 0.3 kg DC
Mounting
On 35 mm DIN-rail
Power supply alternatives
Model description
LD-64
LD-64
LD-64
LD-64
LD-64
AC
115V AC
DC
36–55V DC
HV
Power supply
230V AC
115V AC
24V DC
48V DC
95–240V AC±10%
+15/–10%
+15/–10%
+50/–50%
+15/–25%
110–240V DC±10%
Frequency
48–62Hz
48–62Hz
–
–
48–62Hz / –
Fuse, F2
100mA S
100mA S
1.6A S
1.6A S
1A T Wickmann
5x20 mm
5x20 mm
5x20 mm
5x20 mm
Littelfuse
Littelfuse
Littelfuse
Littelfuse
Power consumption
20mA
40mA
3W
3W
40mA
Isolation, RMS
Power supply
3 000V
3 000V
1 500V
1 500V
3 750V
* Synchronous protocols can be transmitted under certain circumstances.
See ”selection of bits” page 17.