* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.

This earthing point should have a low impedance connection to the conductive enclosure of the apparatus

cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing

system of an installation and may be directly connected to the protective earth.

Generic I/O Relay Output
Electrical specification

One change over contact

Switching voltage

Max 40 VAC/DC

Switching current

Max 500 mA AC/DC

Electrical endurance

5 x 10

5

operations @ 20 W / 20 VA Resistive load

Transmission range

Cable Length

≤15 m

Connection

Detachable screw terminal (DCE )

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Isolation to

Power port 3 kV

rms

50 Hz 1 min

ISDN line 2 kV

rms

50 Hz 1 min

RS-232 1.5 kV

rms

50 Hz 1 min

RS-485 1.5 kV

rms

50 Hz 1 min

I/O input 2 kV

rms

50 Hz 1 min

Shielded cable

Not required*