4.5 Adjustments
4.5.1 Index speed adjustment
Speed is set via the DELAY function. The lower value, the faster the bottles will move from inlet to
filling and capping.
Press ADJUST (the capping machine will enter lower position)
Set speed on DELAY potentiometer, 0,5 = minimum time (~ fast process), 10 = maximum time
(~ slow process)
Press START to save the value (note the value)
Turn DELAY back to 0
Press ADJUST again to return to normal mode
The value is saved when the machine is turned off.
4.5.2 Bottle ejector speed adjustment
Speed is set via the DELAY function. The lower value, the faster the bottles will be pushed onto the
outlet tray.
Press ADJUST (the capping machine will enter lower position)
Set speed on DELAY potentiometer, 0,5 = minimum time (~ fast process), 10 = maximum time
(~ slow process)
Press STEP to save the value (note the value)
Turn DELAY back to 0
Press ADJUST again to return to normal mode
The value is saved when the machine is turned off.
4.5.3 Capping time adjustment
Capping time adjustment is set via the DELAY function. The lower value the adjustment is set at, the
shorter time the capping head will use on screwing the cap into place. Note: If the time is too short
the cap might not be fastened enough.
Press ADJUST (the capping machine will enter lower position)
Set speed on DELAY potentiometer, 0,5 = minimum time (~ fast), 10 = maximum time (~ slow)
Press CAP to save the value (note the value)
Turn DELAY back to 0
Press ADJUST again to return to normal mode
The value is saved when the machine is turned off.
4.5.4 Round table speed adjustment
See section 2.4.2