beautypg.com

Watson-Marlow 101F User Manual

Page 7

background image

7

Care and maintenance

Scheduled m aintenance of the 101U/R pum p is not r equired. If har mful liquids are spilled on to the pump, the

pumphead should be washed down thoroughly. The case and pum phead should be c leaned with detergent and water.

Do not use strong solvents.

101F/R Specification

Nominal rotor speed

4rpm, 4.8rpm

20rpm, 24rpm

Volatge/frequency

100-120/220-240V 50/60Hz

Power consumption

25VA

Fuse rating

Type T (anti-surge) 0.08A

Operating temperature range

5 to 40C

Storage temperature range

-40C to 70C

Weight

1.7kg (4lb)

Noise

<70dBA at 1m

Standards

IEC 335-1, EN60529 (IP21)

Machinery Directive 2006/42/EC

EMC Directive 2004/108/EC

101U/R Specification

Maximum rotor speed

2rpm, 32rpm

Volatge/frequency

100-120/220-240V 50/60Hz

Control ratio

25:1

Power consumption

25VA

Fuse rating

Type T (anti-surge) 0.1A

Operating temperature range

5 to 40C

Storage temperature range

-40C to 70C

Weight

2.2kg (4.8lb)

Noise

<70dBA at 1m

Standards

IEC 335-1, EN60529 (IP21)

Machinery Directive 2006/42/EC

EMC Directive 2004/108/EC

Specific drive performance details such as loaded dr ive speed variation against m ains supply voltage fluctuation and

drive stability from a cold start to normal operating temperature are available on r equest. For further information please

contact Watson-Marlow Technical Support Department.

This manual is related to the following products: