6. CLEANING.

6.1.

Cleaning of the frame.


The FlexFeed 20 frame is not connected to the mains (110/220 VAC), and it is therefore
quite safe to use water or a similar liquid for the cleaning of the frame. If the rotary table
must be removed in order to be cleaned, this can be done as follows:

Fig. 12



Remove the cover plate over the bottle exchanger.

Loosen the Allen screw and remove the bottle feeder (1)

Loosen the Allen screw (2) and lift the bottle guide (3) off.

Remove the Allen screw for the guide rail adjustment (4) and the guide rail with the picking
wheel can be put to one side.

The rotary table can be removed and cleaned.