5.1.5. Adjusting the rotary table bottle guide

Fig. 10


Loosen the Allen screw (1) and adjust the bottle guide (2) to the greatest possible distance
to the outer guide rail. The greatest distance is found by letting a bottle run along the bottle
guide Fig. (2) When it reaches the picking wheel (Fig. 4) the bottle must enter the bottle
sluice.

Place some bottles on the rotary table, and each time the release button is pressed, the
system will exchange a bottle. Carry out a number of exchanges in order to check the
adjustment.

FlexFeed 20 has now been adjusted to the required bottle.

Finally the filling needle must be positioned and adjusted over the bottle in the filling station,
and the filler can then be programmed.