beautypg.com

Triplett TDR User Manual

Page 7

background image

Page 6

3. Specifications

Approximate Range

Coaxial Cable: 6400ft max (1999m)

Structured Wiring: 2500ft max (750m)

Telephone Cable: 2500ft max (750m)

Resolution

0.1ft < 100ft & 1ft > 100ft

Accuracy

+/- 3% or 1.5ft

Vp Range

0 to 99%

Cable Library

39 Standard Cable Types

Tone Generator

Oscillating between 810Hz and 1110Hz

Display

Alpha-numeric LCD

Connector

BNC

Battery

9v PP3 Alkaline cell

Battery Life

Better than 2000 tests

Temperature

32 to 112 deg F (0 to 40 deg C)

Storage Temp.

0 to 150 deg F

Dimensions

7.9” x 3.1” x 1.4”

Weight

less than 0.55lb

Safety

IEC1010-1

EMC

To EU directives

UL, CUL and CE

Approved

4. Principles of Operation

The TDR works by measuring the time taken for a signal to travel to the far
end of the cable (or to an intermediate fault) and to return.

The velocity at which the signal is transmitted (Velocity of Propagation ie.
Vp) will depend on the characteristics of the cable under test.