NOTE:
Verify there’s adequate grease in the gear box.
Gears and bearings are to be lubricated using a lithium based grease.
Disassembly of a power unit voids warranty, except when performed by a TRI
TOOL Inc. designated repair technician. A letter of designation is required.
AIR MOTOR LUBRICATION
No direct maintenance is normally required on the air motor.
However, the air supply must flow through a filter/regulator/lubricator (FRL)
unit or separate units before arriving at the air motor.
The FRL unit must be maintained as required, frequency dependent on the basic air
supply, to keep the water trap drained, filter cleaned and the lubricator oil reservoir
filled so that a drop of oil every 2 to 5 seconds is flowing.
If the BOILERMASTER™ is to be left idle for 24 hours or more after being run
on ‘wet’ air, it is advisable to squirt oil directly into the air motor inlet and run
the motor for 2 to 3 seconds.
This will prevent rusting and freezing of the rotor vanes.