beautypg.com

Tri Tool 75-0115 Air Caddy User Manual

Page 15

background image

15

92-0896 : Orig. 001215

Model 75-0115 Air Caddy

NOTE:

Drops per

Regulator

Air Drive

Minute

Pressure

Source

1 - 2

Do not exceed the

Small

Manufacturers

2 - 3

recommended Air

Medium

Pressure Rating for

3 - 4

the Air Motor used.

Large

Lubricator Flow Rate

When the air flow stops, the lubricator stops the flow of oil.

As a general guideline for adjusting the amount of oil flowing to an air motor, the
operator can observe the amount of oil being exhausted from the exhaust port(s)
on the air motor.

If the amount of oil builds up rapidly at the port(s), the rate is too high.

The operator should reduce the number of drops of oil per minute accordingly.