FIREPLACE INSTALLATION

Continued

CHECKING GAS CONNECtIONS

WARNING: Test all gas piping and connections for

leaks after installing or servicing. Correct all leaks at

once.

WARNING: Never use an open flame to check for

a leak. Apply a noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct all leaks

at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect fireplace and its individual equipment shutoff valve

from gas supply piping system. Pressures in excess of 1/2 psig

(3.5 kPa) will damage fireplace gas regulator.

2. Cap off open end of gas pipe where equipment shutoff valve

was connected.

3. Pressurize supply piping system by either opening propane/LP

supply tank valve for propane/LP gas fireplace or opening main

gas valve located on or near gas meter for natural gas fireplace,

or using compressed air.

4. Check all joints of gas supply piping system. Apply noncor-

rosive leak detection fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

5. Reconnect fireplace and equipment shutoff valve to gas supply.

Check reconnected fittings for leaks.

test Pressures Equal to or Less than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 33).

2. Pressurize supply piping system by either opening propane/LP

supply tank valve for propane/LP gas fireplace or opening main

gas valve located on or near gas meter for natural gas fireplace,

or using compressed air.

3. Check all joints from propane/LP supply tank or gas meter to

equipment shutoff valve (see Figure 34 or 35). Apply noncor-

rosive leak detection fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

Figure 33 - Equipment Shutoff Valve

Closed

Equipment

Shutoff

Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Figure 34 - Checking Gas Joints for Propane/LP Gas

Fireplace

Propane/LP

Supply Tank

Gas Valve

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Equipment

Shutoff

Valve

PRESSURE tEStING FIREPLACE GAS CONNECtIONS

1. Open equipment shutoff valve (see Figure 33).

2. Open propane/LP supply tank valve for propane/LP fireplace

or main gas valve located on or near gas meter for natural gas

fireplace.

3. Make sure control knob of fireplace is in the OFF position.

4. Check all joints from equipment shutoff valve to gas valve (see

Figure 34 or 35). Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct all leaks at once.

5. Light fireplace (see Operating Fireplace, page 23). Check all

other internal joints for leaks.

6. Turn off fireplace (see To Turn Off Gas to Appliance, page 23).