Installation procedures – Thermon HeetSheet User Manual
Page 3

4. Illustration C depicts roll style 2 installation. For strap or
banding requirements for roll style 1 configuration, refer
to typical HS-2 banding placement.
Illustration C: Strap/Banding Placement
5. Banding on vessels smaller than 3 m in diameter may be
installed completely around the vessel (see Illustration D).
6. For vessels larger than 3 m in diameter, circumferential
banding should not be used. Banding on larger vessels will
stretch creating possible air gaps and reduction of heat
transfer rates. Segment the banding and attach using one
of the following methods:
A. Welded stud
B. Anchor plate
Refer to Illustration E for permanent segmental banding.
Illustration D: Permanent Circumferential Banding
HeetSheet
(HS-4 shown)
Stainless Steel
Banding
Crimp Seal
2
7. Installations where additional heat is required on the coni-
cal portion of the vessel may be traced with tubing in the
form of hairpin loops. Secure tubing with welded studs or
anchor plates as outlined in Step 6. Use heat transfer com-
pound on tracers (see Illustration F).
HS-2
HS-4
HS-8
305 mm
305 mm
305 mm
305 mm
305 mm
305 mm
305 mm
150 mm
150 mm
150 mm
305 mm
305 mm
305 mm
150 mm
100 mm
200 mm
200 mm
100 mm
Steel Straps or
Stainless Steel
Banding
Illustration F: Conical Installation
To Trap and Condensate
Return Manifold
Tracer Tubing With
Heat Transfer
Compound
40 x 6 mm
Steel Strap
Welded Stud
Attachment
Method
Illustration E: Permanent Segmental Banding
Method A:
Welded Stud
Method B:
Anchor Plate
Welded Stud
40 x 6 mm Steel Strap
Flat Washer
Lock Washer
Nut
Stainless Steel Banding
Weld
Anchor Plate
Crimp Seal
INSTALLATION PROCEDURES