Thermon PETK-10 User Manual
Page 6
Step 5
Insert the bare conductor of both the Cold Lead/Heating Cable and Heating Cable into the crimp connector and
ensure complete overlap of conductors inside the crimp connector. Crimp the crimp connector with matching crimping
tool. Follow the same procedure for terminating the braid of the Cold Lead/Heating Cable and Heating Cable. For
cable type TESH 600 up to TESH 8000, the heating cable conductor shall be folded double within the crimp*. For the
correct Crimp Connector type, see table page 3.
Step 6
Place the Spacer between both crimped connectors and ensure that both the leads and crimped connector are
properly placed inside the slots. Put a rich amount of silicone sealant on the crimped connectors and in the slots.
*Sealant on Crimp connectors.
Step 7
Slide the Housing over the assembled connections. Ensure assembled connection is positioned in the centre of the
Housing. Fill one end of the Housing with sealant ensuring that there are no air pockets and push the grommet into
the Housing. Ensure the joint and cable ends are held in position. Tighten the screw cap, repeat the operation at the
other end. Wipe off excessive sealant.
Installation Instructions
5
Form TEP0107U-0512 © Thermon Manufacturing Co. Information subject to change.