10.
Install M25 power gland and M25 blind plug.
For in-line splice, T-splice, or end termina-
tion, install additional M25 blind plug (order
M25-B-EXE separately) instead of M25 power
gland.
11.
Install M25 power gland and M25 blind plug.
For in-line splice, T-splice, or end termina-
tion, install additional M25 blind plug (order
M25-B-EXE separately) instead of M25 power
gland.
13.
Complete system wiring. Terminal set screws
shall be tightened to a torque value of 1.4 Nm
(12.4 lb-in). See page 5 for wiring details.
14.
Install junction box lid and twist hand tight.
Insert screwdriver into ratchet slots located
on side of junction box base.
15.
Use screwdriver to ratchet on junction box lid.
Lid will rotate 30 degrees.
16.
Lid latch mechanism fully engaged. To remove
lid, repeat steps 14 and 15 but in the opposite
direction..
A1.
Locate bus connection (HPT and FP only) and
cable as shown. Cut end of cable at angle to
aid in piercing grommet. Leave additional
cable for expansion loop.
12.
Install quick mount terminal blocks and tighten
screws (if necessary).
Two Cable Layout Tips
A2.
Insert two cables into expediter.