Terminator, Ze-b beacon, Installation procedures – Thermon ZE-B Beacon Terminator User Manual
Page 4
Locked
Position
13.
To remove cap, de-energize circuit, lift latch
mechanism, and unscrew cap.
12.
Engage threads. Rotate light module cover
clockwise and tighten cap securely. Make sure
latch mechanism is in the locked position.
11.
Arrange crimped leads to fi t inside light mod-
ule base. Slide the light module cover over
light module.
Light Module
Cover
Lens
Expediter
Assembly
Light Module
Unlocked
Position
9.
Snap on crimp insulators.
Light Module
Expediter
Assembly
Crimp
Insulators
10.
Slide silicone caps over crimp insulators.
Install Light Module to Expediter.
Silicone Cap
Terminator
TM
ZE-B Beacon
INSTALLATION PROCEDURES