Re-using items (1) and (2) from the safety cap, assemble the waterproof RJ-45

connector as shown below:

NEMA 4 Enclosure

Safety Cap

2

1

2

3

1

4

5

6

Waterproof RJ-45

Connector Assembly

Assembly Instruction

I. Assembly Diagram
*Actual parts may vary, please use
this diagram for general guidance.

Follow the procedure below to install your TT™2400 device:

Note: The TT™2400 now supports MDI/MDI-X and no longer require the use

of cross over cable to connect directly with a computer.

1. Select a suitable place on the network to install the TT™2400. For best wireless reception

and performance the external antenna should be positioned within Line of Sight from the

AP with proper alignment.

2. Connect the TT™2400 to the ODU side of the PoE Injector via a straight Ethernet cable

(Cat-5), then connect the NET side of the PoE Injector to either a computer or an Ethernet Switch.

Check the LEDs on the TT™2400 to confirm if the status is okay. At this point the PWR and LAN LEDs

should be on green. The WLAN light should light up once the unit is associated wirelessly with another

wireless device. However at this point the unit is still in factory default setting so do not the alarmed

that the WLAN light doesn’t light up.

3. Connect the 48VDC power adapter to the power jack on the PoE injector to power on the TT™2400.

For detailed instructions on how to configure the TT™2400, please refer

to www.teletronics.com/Support.html

Hardware Installation

Default IP Address in Client Bridge Mode (SU): 192.168.10.241

Web Control Interface

Always double check for any missing parts before deployment. Next step is to set up the

computer Ethernet interface for configuring the TT™2400. Since the default IP Address of the

unit is on the 192.168.10.x IP range in both Client Bridge and AP mode you’ll need to set

the computer Ethernet interface within the same IP subnet, such as 192.168.10.66.

Quick Installation

Default IP Address in Access Point Mode (AP): 192.168.10.240

Default Login/Password: Nothing needs to be typed in for login and password authentication.

PC

EXTERNAL ANTENNA

CONNECTOR

POWER OVER ETHERNET

CONNECTION

DC POWER

CONNECTION

TO NETWORK

GROUND

CONNECT TO

GROUND

TOP VIEW