TE Technology TC-24-25 User Manual
Page 28

28
Interpret:
Fixed-point gain in minutes.
Multiply desired derivative gain by 100.
0.01 min would be 1 decimal.
1.00 min would be 100 decimal.
17. LOW EXTERNAL SET RANGE
Write Command:
20 hex
Read Command:
54 hex
Interpret:
Value mapped to zero voltage of Input2.
18. HIGH EXTERNAL SET RANGE
Write Command:
21 hex
Read Command:
55 hex
Interpret:
Value mapped to 5 volt or maximum voltage of Input2.
19. ALARM DEADBAND
Write Command:
22 hex
Read Command:
56 hex
Interpret:
Temperature Input1 must move to toggle
alarm output.
20. HIGH ALARM SETTING
Write Command:
23 hex
Read Command:
57 hex
Interpret:
Temperature reference to compare against Input1 for high
alarm output.
21. LOW ALARM SETTING
Write Command:
24 hex
Read Command:
58 hex
Interpret:
Temperature reference to compare against Input1 for low
alarm output.
22. CONTROL DEADBAND SETTING
Write Command:
25 hex
Read Command:
59 hex
Interpret:
Temperature or count span Input1 must move to toggle
control output.
23. INPUT1 OFFSET
Write Command:
26 hex
Read Command:
5a hex
Interpret:
Value to offset Input1 by in order to calibrate external
sensor if desired.
24. INPUT2 OFFSET
Write Command:
27 hex
Read Command:
5b hex