beautypg.com

Troubleshooting, Problem, Cause/remedy – System Fidelity RS-250 User Manual

Page 15

background image

TROUBLESHOOTING

PROBLEM

No power when the receiver is turned on.

No sound.

There is sound in one channel only.

High buzzing.

Weak bass and poor stereo perspective

Distortion of sound.

The LCD display does not display

any information.

_ERROR 1 _ is displayed on the LCD display

The unit does not switch between inputs

CAUSE/REMEDY

-Switch on the electric current at the socket.

-Check that the plug has been correctly inserted into the

socket.

-The internal fuse has blown and must be replaced by a

qualified service technician.

-The power cord has been damaged and must be replaced

-The receiver has not been turned on from stand-by mode.

-The volume control is set at a minimum

-The speaker cables have not been correctly connected.

-A wrong input source has been selected.

-No input source has been connected.

-The balance control is not correctly adjusted

-The audio input cables have been incorrectly connected

or damaged.

-The input source is defective.

-The speaker cables have been incorrectly connected or

damaged.

-The speakers are defective.

-The audio input cables have been incorrectly connected

or damaged.

-The ground cable for the record player has not been

connected.

-The record player pick-up is defective.

-The speaker connection is out of phase. Check that the

positive and negative poles have been correctly

connected, both at the back of the amplifier and at the

back of the speaker.

-Some of the conductor wires of the speaker cable are in

contact with each other which causes distortion.

-Bass and treble controls are set too high in relation to

speaker specifications.

-The volume is set too high.

-The receiver is defective and should be serviced by a

qualified technician.

-The receiver is defective and should be serviced by a

qualified authorized service.

- The receiver is defective and should be serviced by a

qualified authorized service.

-The receiver is defective and should be serviced by a

qualified authorized service.

14

This manual is related to the following products: