3. PRE-INSTALLATION CONSIDERATIONS
§ Please inspect the unit for any shipping damage. If the lift has been damaged during transport,
do not proceed with the installation. Please contact SVS.
§ Ensure that you have the require space to install the Column Lift with your screen attached.
§ Ensure that your cabinet will support the weight of the Column lift and screen.
§ Consider how you will install the necessary cabling for the lift and screen (control, audio, video,
and/or AC Power cables).
§ Do not install the screen on the lift until the lift, hardware, and any other accessories have been
properly installed and are operational. Failure to maintain proper clearance could result in
damage to the screen, furniture, and/or lift.
§ The upper limit of the Column Lift has been adjusted at the factory. Adjustment of the upper
limit by other than SVS personal will void the lift warranty.
§ The weight of the screen should be balanced right to left on the lifts telescoping column.
§ Consider how you will access the lift and electrical connections after the lift is installed.
4. DIMENSIONAL INFORMATION
§ The Column Lift is 12.67-inches (32.18 cm) wide by 12-inches (30.48 cm) deep by 49.25-
inches (129.54 cm) high in the lowered/closed position. The raised/open height is 100.25-inches
(254.5 cm).
§ Inside cabinet height will need to be at least 49.25-inches. And 50 3/16-inches with the
Closure Adapter Kit.
§ Inside cabinet width will be determined by the width of the plasma/LCD screen. Remember
to allow adequate clearance on each side of the screen. If you are using the Closure Adapter
Kit your inside width will need to be at least 24-inches.
§ Inside cabinet depth must be at least 12-inches to accommodate the Column lift for Plasma
and LCD screens with a combined screen and mount depth of 4-inches or less. If you screen
and mount depth are greater than 4-inches, the inside depth will need to be more than 12-
inches.
§ Inside cabinet depth will need to be at least 15.5-inches with the Closure Adapter Kit. The
Closure Adapter extends 5 1/8 – inches from the front of the telescoping column, if the
combined depth of your screen and screen mount is more than 5 1/8 – inches, you will
require additional depth.
See Column Dimension in Section 9.
5. LIFT INSTALLATION
Before beginning the installation, check the dimensions of the SVS Column Lift and plasma/LCD
screen with the available space within the cabinet.