eFlo Electronic Flow Meter Operations Manual

Super Systems Inc.

Page 5 of 25

Ambient Temperature Limits

-10°F to 150°F (-20°C to 65°C)

Flow Output Signal (Linear)

4-20mA

Maximum Output Signal Load

500

Ω

Input Control Signal (Linear)

4-20mA

Response Time

1 – 10 seconds

Communications

RS232, RS485

Communication Protocol

Modbus RTU

Pressure Drop @ 100% Capacity

See Calibration Report for specific pressure

drop.

5” wcg (Standard Model)

10” wcg (Standard Model)

Flow Meter Pressure Limits

The pressure will be calibrated to user-

specified requirements. See the Calibration

Report for more details.

5 psig – maximum allowable

Table 1 - eFlo Specifications

Replacement Parts

Replacement parts can be ordered for the eFlo unit when and if needed. Contact SSi at (513)

772-0060 to order parts.

Part Number

Item

Explanation

33149

Motor and Shaft

Drives the Valve Needle open and

closed to maintain the correct gas

flow.

34224

O-Ring, eFlo Body & Plate

O-ring that seals the three

components of the eFlo Body

(upper, lower, and middle),

Bottom Plate, and Motor Plate.

37315

O-Ring, eFlo Valve Needle Shaft

O-ring that seals the Valve

Needle Shaft against the Motor

Plate.

37321

Gasket, eFlo Motor Plate

Gasket that seals the eFlo Motor

Plate to the Motor Spacer Block

and Motor.

34603

Grommet, Cylinder Adjustment

Grommet on top of the Electronic

Housing.

34692

Calibration Test Ports

Two pressure ports located on

the side of the Body of the meter.

These ports allow the pressure

drop to be measured for

calibration verification of the

meter.