Super Systems TS Manager User Manual
Page 18

Super Systems Inc. Page 18 of 22 Touch Screen Manager Operations Manual
• Min. The minimum value displayed in the trend line on the chart.
• Max. The maximum value displayed in the trend line on the chart.
• Color (solid color shown). The color of the trend line as it will appear on the chart.
• Width. The width of the trend line.
• Format. The number of decimal places shown in the numerical values for that particular
trend line.
• Units. The units shown for that particular trend line (degrees F, percentage, etc.).
• Expression. A mathematical operation performed on each value displayed on the trend
line.
x
is the original value; the mathematical operation shown indicates the operation
performed on
x
before the newly calculated value is included on the trend line.
• colTestValue. A test value entered to test the mathematical operation shown in the
Expression field.
• Total. The value resulting from performing the mathematical operation shown in the
Expression field on the value shown in colTestValue.
TS Manager Batch Mode (Applies to version 1.1.0.21 and higher)
Starting with TS Manager version 1.1.0.21 and up, there is an optional batch mode that will
automatically download new data and export any new notes to SD Recorder without the need to
start up the TS Manager software.
Adding the TS Manager Location to the System Path
The first step in setting up the batch mode for the TS Manager is to add the TS Manager’s
installation path to the system’s Path variable. This will simplify the execution of the
application. From the Start Menu, click on the “Control Panel” option.
In Windows XP: Once the Control Panel is opened, double-click on the “System” icon to open the
System Properties screen.
In Windows Vista or Windows 7: Make sure that the View By option is set to Large Icons or Small
Icons, as shown at right (a Medium Icons option may also be present).
Then click on the System (
) icon, and then the Advanced System Settings option
(
) along the left of the screen.
There will be a few tabs across the top of the screen. Click on the “Advanced” tab to select it.
From the “Advanced” tab, click on the Environment Variables… button (See Figure 29). A prompt
asking whether you want to allow this action may appear; if it does, allow it.