Studio Technologies 68A 2005 User Manual
Page 18

Issue 2, January 2005
Model 68A/69A User Guide
Page 18
Studio Technologies, Inc.
for Surround
the 11- or 12-o’clock position. The modi-
fi ed log mode more closely matches the 
monitor level control performance found 
in many audio consoles. As such it is 
selected as the default mode.
It’s important to note that changing the 
level control response confi guration will 
impact the reference level. Changing from 
modifi ed log to true log, or vice-versa, will 
change the reference level. Technically, 
the mathematical value stored as the 
reference level does not change, but the 
loudness that is heard by the operator will 
change. Be warned! Changing the level 
control response may require the refer-
ence level to be recalibrated.
Level Control Auto Mute All
The level control auto mute all function 
automatically mutes the monitor output 
channels whenever the rotary level control 
is in its fully counterclockwise position. In 
some applications it may be desirable to 
disable this function. When disabled, the 
rotary level control adjusts the monitor 
output level over the approximately 72 dB 
range; no automatic muting takes place.
Reference Level
For audio-with-picture applications it’s criti-
cal that mixing be done in reference to a 
known monitor loudspeaker level. This is 
often referred to as mixing to “85 dB” on 
the monitors. The Model 69A Control Con-
sole allows a precise monitor output level 
to be stored, and then enabled by pressing 
the button labeled REF. Setting the refer-
ence level is very simple:
1. Set up a precision sound pressure
level (SPL) measuring device at the 
desired listening location.
2. Place the StudioComm system in the
normal operating mode, not the confi g-
uration mode. Be certain that the refer-
ence and dim functions are not active.
3. Use the Model 69A Control Console
to select the input source that contains 
the desired reference signal source, 
e.g., pink noise.
4. Select the desired output, surround
or stereo.
5. Observing the SPL meter, adjust the
Model 69A’s rotary level control until 
the desired reference output level has 
been reached.
6. Being careful not to touch the position
of the rotary level control, enter the 
confi guration mode by pressing and 
holding the confi guration button locat-
ed on the Model 69A’s back panel.
7. Once the confi guration mode has been
entered, the monitor outputs will mute. 
Press and hold the reference button 
until its associated LED lights. This will 
take approximately 5 seconds. The 
LED will light to indicate that a “snap-
shot” of the new reference level has 
been taken.
8. To store the new reference level in
memory, exit the confi guration mode 
by again pressing and holding the con-
fi gure button.
This level is now permanently stored as 
the reference level. Only by repeating the 
procedure can the value be changed.
Once the confi guration mode has been 
exited, the monitor output channels will 
again become active. Confi rm that the cor-
rect level has been stored by pressing the 
reference button. The SPL meter should 
