Combustible Items Include:

Wood

Paper

Fabric

Chemicals

Wall or roof insulation



Moving Objects Include:

Overhead doors

Vehicles on lifts

Cranes

Hoists

Car wash equipment


When installing the infra-red heater system, the minimum clearances to combustibles must be maintained. These
distances are shown in Chart below and on the heater. If you are unsure of the potential hazards, consult your local
fire marshal, fire insurance carrier or other qualified authorities on the installation of gas fired infra-red heaters for
approval of the proposed installation. Install the warnings card supplied with each heater and complete the blank
spaces using the clearances from combustibles table below. See Section 21 for a printed copy of the warnings
card.


Minimum clearances shall be measured from the outer surfaces as shown below:


MINIMUM CLEARANCES TO COMBUSTIBLES

MODEL

Mounted Horizontally

Mounted at 35º Angle

Angle

Mounting

SIDES CEILING

BELOW

BELOW

FRONT

REAR

w/Standard

Reflector

w/Reflector

Extension

w/Standard

Reflector

w/Reflector

Extension

w/Standard

Reflector

w/Reflector

Extension

DK30

DK35

DK33

DK40

30”

36”

72”

100”

72”

100”

36”

50”

30”

(degree)

0º min

35º max

DK60

DK70

DK66

DK80

48”

48”

98”

137”

98”

137”

48”

68”

36”

0º min

35º max

DK100
DK120

48”

64”

128”

180”

128”

180”

60”

84”

48”

0º min

35º max

DK132 DK160
DK140

60”

64”

136”

190”

136”

190”

64”

90”

48”

10º min

35º max


NOTE:

The clearance to combustible materials noted above must be maintained at all times and the same

clearance distances must be adhered to from any other materials that may be damaged by temperatures 90

o

F

above the ambient temperature. It is the installer’s responsibility to ensure that building materials with a low
heat tolerance (such as plastic, vinyl siding, canvas, tri-ply etc.) which may degrade at lower temperatures are
protected to prevent degradation. Clearances to combustibles are posted on the reflector near the control end
of the heater.



5