beautypg.com

C) troubleshooting chart – Space Ray DK Series User Manual

Page 17

background image

Form #43219010

Sept 2012

C) TROUBLESHOOTING CHART

TROUBLE

POSSIBLE CAUSE

SOLUTIONS

Heater is not glowing
red…

 The supply gas pressure is too low.

 Improper size of gas piping.


 The orifice is clogged.
 Incorrect orifice size.

 Check the manifold gas pressure and

adjust if necessary.

 If you are not sure of the performance,

use the NFPA 54 gas pipe sizing table.

 Clean the orifice.
 See the instructions for correct orifice

size and replace if necessary.

Heater will not
attain the desired
temperature…

There is insufficient heat in the building

for heat loss (i.e., not enough heaters).

 The thermostat sensing bulb is

incorrectly placed.



 The thermostat is out of calibration.

 Conduct heat loss and add heaters or

other source of heat as necessary.

 Reposition as necessary for proper

operation. NOTE: The sensing bulb
should be shielded from direct radiation
to prevent short cycling of the heater.

 Recalibrate (if possible) or replace.

Flames flaring up,
outside of emitter
surface…

 The gas pressure is too high.

 Incorrect orifice size.

 Incorrect type of gas supplied to the

heater.

 Not enough combustion air.

 Check the manifold gas pressure and

adjust if necessary.

 See instructions for correct orifice size

and replace if necessary.

 Check the nameplate to identify the

correct type of gas the heater is equipped
to operate.

 Clean the emitter with compressed air.










































16