SONOSAX MINIR82

- User interface V4.2

Page 21 de 32

SETUP > INPUTS SETTINGS > LINE IN LEVEL

The sensitivity of LINE INPUT 3 – 4 can be set so that the input level can reach 0dBFs on the A/D
converter, e.g. if +15 is selected then a line level of 15dBu will reach 0dBFs. Choices are:

• +15 dBu / + 6 dBu / 0 dBu / -10 dBu

4.5.5 TIME CODE SETTINGS

The MINIR82 can either receive or generate a Time Code at any of the conventional formats; the following
sub-menus are used to set the required Time Code parameters.









SETUP > TIMECODE > SOURCE
This menu sets the source of the Time Code; it can be taken either form its own internal Time Code
generator or from an external generator connected on the mini-jack as described below.

• External Jam Sync

the TC is jammed on an external source

• External No Jam

the TC is read continuously

• Internal

the TC is internally generated but its output on the mini-jack is disabled

• Output

the TC is internally generated and is available on the mini-jack connector


NOTE:

while selecting

[OUTPUT], a frame rate other than [AUTO] (states for auto detect) must be

selected in the menu

[TIME CODE FORMAT]. If [AUTO] is selected, a warning is posted on the

screen and a bip tone is heard.

NOTE:

if

[OUTPUT] is selected in PLAYER mode, the Time Code of the played file is outputted


SETUP > TIMECODE > FORMAT
When [EXT JAM SYNC] or [EXT NO JAM] is selected, the MINIR82 detects automatically the format (also
called Frame Rate) of the incoming Time Code; however specifying a format allows to check the validity and
the accuracy of the incoming Time Code, in this case an incoming Time Code having a format different from
that specified or not within the standard tolerances will trigger an alarm.
The available Time Code formats are:

• 23.976 - 24 - 25 - 29.97 Non Drop - 29.97 Drop - 30 Non Drop - 30 Drop - AUTO


SETUP > TIMECODE > RUNNING MODE
Two possible choices:

• FREE RUN

the Time Code is absolute and linear. It runs continuously and never stops

• RECORD RUN

Time Code is generated only while recording


SETUP > TIMECODE > SET MANUAL
This menu is used to set the Time Code value manually.

SETUP > TIMECODE > SET FROM TIME
The value of the Time Code is grabbed from the real time clock of the MINIR82 (system time).