beautypg.com

Operation programming, Sun function, Wind function demo mode time delays ip – SOMFY SOLIRIS RTS 24V KIT User Manual

Page 2

background image

IP

SUN Function

(Intermediate Position)

WIND Function

DEMO Mode

TIME DELAYS

IP

The

controls and provides a measure of protection for a retractable

awning according to the sun and wind conditions.
The WIND and SUN thresholds can be adjusted by two potentiometers, one for wind speed and
the other for daylight intensity.
The adjustment range is between 6 - 31 miles per hour for the WIND and between 0 to 50 kilolux
for the SUN
By using the

it is possible to configure the functioning of the

receiver (wind only or wind/sun). Please refer to the

operating instructions.

A short UP/DOWN movement of the awning indicates the modification of the sensor settings.

SOLIRIS RTS

TELIS SOLIRIS RTS transmitter,

TELIS SOLIRIS RTS

sensor

When the intensity of the
daylight exceeds the thre-
shold set by the SOLIRIS
RTS

, a DOWN order is

sent to the awning after 2 minutes.

The awning goes to the intermediate position
IP, (see the motor installation instructions) or to its down end
limit position if no intermediate position has been memorized.

sensor

When the wind
speed exceeds
the threshold
set by the
SOLIRIS RTS

, an UP

order is given
to the awning after 2 seconds

sensor

The mode is selected by turning the wind
potentiometer clockwise to the limit.
In this mode all time delays are reduced to facilitate
installation. The wind threshold is 6 mph.

The change of setting "In" or "Out" of the Demo Mode
is confirmed with a brief Jog of the motor. This function
can be used to confirm that the sensor is communicating
with the motor's receiver.

This is the elapsed time required for the motor to respond
automatically or manually (using the transmitter) to the change
in sun or wind conditions.

* It is possible after 30 sec. to give a

down order with the RTS transmitter

NOTE: Do not leave RTS sensor in demo mode when

installation is completed.

SUN appearing timing
SUN disappearing timing
WIND appearing timing
WIND disappearing timing*

When the daylight
level falls below the
threshold setting, a
variable time delay
from 15 to 30 minutes is activated
(depending on the sun prescence duration).

This feature avoids frequent movements of the awning
on cloudy days.

As long as the
measured
wind speed is
higher than the
adjusted threshold, all commands
are prevented from operating.
(manual control or automatic control).

After this time delay, an
UP order is given to
the awning.

Any manual command
given during this cycle will
override the automatic
operation. The SOLIRIS RTS

will not then function automatically until the

daylight exceeds the threshold limit again.

sensor

When the wind
speed falls
below the
threshold setting,
the SUN function
remains inoperable

for 12 minutes,

although it is possible
after 30 seconds, to
give an order with the RTS Transmitter.

-

Demo

after 15 to 30 min.

after

12 min.

after

30 sec.

after 2 sec.

+

-

+

-

Demo

+

A. To Enter the "Programming mode"

C. To delete all the sensors and record a new one

The motor must be in

to record a

One

be memorized into several motors.

It is not recommended to memorize more than 1
into the motor’s memory.

programming mode

SOLIRIS RTS

.

SOLIRIS RTS

SOLIRIS RTS sensor

sensor

sensor can

Activate the receiver's memory
by pushing (for more than 2
seconds) the

of a transmitter already

recorded in the motor's memory.

programming

button

The awning jogs briefly
DOWN/UP. This confirms
the motor is in
programming mode.

Press

on

the programming
button of the
SOLIRIS RTS

briefly

sensor

Press for

on the

"programming"
button of the new
SOLIRIS RTS

.

more than

7 sec.

sensor

The awning Jogs briefly (DOWN/UP).
If it is a new sensor :

If the sensor was previously recorded :

it will be

in the motor.

it will be

recorded

deleted.

The awning jogs briefly (DOWN/UP).
The memory of the receiver is cleared
(all previous sensors are erased) and
the new sensor is recorded.

-

+

-

+

-

+

-

+

-

+

-

+

B. To Record or delete a sensor

> 2 sec.

Operation

Programming

4

3

Normal mode

2 min.

30 min.

2 sec.

12 min.

15 to

Demo mode

10

2 sec.

15 sec.

sec.

15 sec.