beautypg.com

Seaward A252 User Manual

Page 12

background image

A252 Portable Appliance Tester INSTRUMENT DESCRIPTION

Flash Test PASS/FAIL lamps glow to indicate the result of the applied test.
When applying a double insulated test via the flash probe a PASS indication should be taken to indicate
that no fault was found at the point of application of the probe.

Test Selector

rotate switch and set to required test as follows


for Class I equipment

Earth Test

also use appropriate Earth Return socket to select 25A or 8A test current.

500v Flash

mainly only used for equipment with inherently high capacitance suppression.

1250v Flash

for normal Class I equipment.


for Class II equipment

2500v Flash

for routine testing of audio/visual appliances and other BS415 related equipment.

3000v Flash

for routine testing.

3750v Flash

for repaired or reconditioned tools.


for Information Technology (IT) Equipment

Functional Earth

100mA continuity test, purely functional - not to be confused with safety Earth Test.

500vDC Megohms for measuring insulation resistance if Flash Test considered too severe.