beautypg.com

Inflation valves & pumps (continued) – Sea Eagle Stealth Stalker 10 (STS10) User Manual

Page 8

background image

Adjust the pressure dial

to read 3.2 PSI which is

the operating pressure

of your Sea Eagle. PSI

is marked in red on the

dial. Never turn the dial

when the device is

under pressure as this

will immediately cause

the instrument to break.

Connect the quick con-

nector at the end of the

power cord into the

quick connector at-

tached to the pump.

To connect the pump to

a 12V battery, use the

cord with alligator clips

at the end of the exten-

sion cord. Connect the

red clip to the positive

pole and the black clip

to the negative pole.

CAUTION: Cross con-

necting wires could

damage the pump and

boat.

If you ordered the

portable battery, con-

nect the battery to the

quick connector onto

the pump.

To charge the portable

battery, plug it into the

charger and then plug

the charger into a

household electrical

outlet. The light on the

battery charger will blink

red until fully charged.

When it is fully charged

the light will be a solid

green.

Keep the pump in its

carry bag to make

transportation easier

and to protect the pump

from sand which could

jam it. The carry bag

has compartments for

the pump, battery hose.

Press the ON button to

begin inflation. The

pump operates in two

stages which can be

identified by the noise of

the turbine at the start,

followed by the piston.

The pump automati-

cally stops once the

pressure is reached.

Air compressors that

are designed for other

uses like tire inflation

(usually around 50 PSI)

can easily harm your

Sea Eagle which works

at a much lower pres-

sure of 3.2 PSI. For this

reason we recommend

only using Sea Eagle

pumps.

7

INFLATION VALVES & PUMPS (continued)