18. Remove two screws holding freezing
compartment brace to cabinet, lift brace up.

19. Lift evaporator platen up and tilt back enough
for bin assembly to clear the base.

20. Remove air baffle.

21. Unplug 7 wire harness connector (at back of
bin).

22. Remove 1 screw at each corner of the base.

23. Lift bin assembly off the base.

Note: Prop evaporator assembly up. A 3' length of
3/4" PVC tubing with one end inserted into the cup
mold and the other against the base will hold it up.

The hot gas valve, fan motor, condenser and
compressor are now exposed for service.

June 2008

Page 31

SCCG50 & SCCP50
Service Manual

Chassis Shown in Front of Bin Assembly