beautypg.com

Adjustments, Mcm1462r, System specifications – Scotsman MCM1462R User Manual

Page 20: This machine uses refrigerant 22, Characteristics

background image

SYSTEM SPECIFICATIONS

The following numbers can be used as a guideline when servicing the CMS1402. There will be some
variation from unit to unit, so allow for that.

THIS MACHINE USES REFRIGERANT 22

Components:

Timer, 1 revolution of the cam takes 8 minutes, harvest time is factory set at 3

1

2

minutes, but is adjustable.

Inlet water valve, water flow in g.p.m. = 1

CUT IN

CUT OUT

Cube size control, reverse acting temperature range . . . . . . . (0

0

F. to +25

0

F.)

High pressure safety, Manual . . . . . . . . . . . . . . . . . . . 400

Bin or Ice Level Control

Maximum Full Height: . . . . . . . . . . . . . . . . . . . . 8" from the base of the ice machine

Maximum Storage Bin Interior Height . . . . . . . . . . . . 8 feet from the base of the ice machine

Characteristics:

Freeze Cycle (90/90/70)
Average Discharge Pressure . . . . . . . . . . . . . . . . . . . . 270 - 240 PSIG

Average Suction Pressure at the end of freeze . . . . . . . . . . . 22 - 24 PSIG

Average Amps . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Average Freeze Cycle Time . . . . . . . . . . . . . . . . . . . . 15 minutes

Harvest Cycle
Average Discharge pressure . . . . . . . . . . . . . . . . . . . . 180 - 200 PSIG

Average Suction Pressure . . . . . . . . . . . . . . . . . . . . . 75 80 PSIG

Average Amps . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.6 (3 phase)

Average Harvest Time . . . . . . . . . . . . . . . . . . . . . . . 2.25 minutes

Refrigerant Charge: 16 lbs. of R-22. If the nameplate charge is different, go by the nameplate.

MCM1462R

April, 1993

Page 20