FOR THE INSTALLER
Final Check List
______1. Is the ice system installed indoors in a
location where the air and water
temperatures are controlled, and where
they do not exceed the design
limitations?
______2. Is there an electrical service disconnect
within sight of the installed machine?
Has the voltage been checked, and
compared to nameplate requirements?
______3. Have all the plumbing connections been
made and checked for leaks?
______4. Has the machine and bin been leveled?
______5. Is there a minimum of 6" clearance at
the back of the machine for proper
service access and air circulation?
______6. Is the water pressure a minimum of 20
psig?
______7. Has the machine been secured to the
bin?
______8. Is there clearance above the top of the
machine for service access?
______9. Is there a water shut off valve installed
near the machine?
______10. Have all of the shipping blocks been
removed?
NME1854 & FME2404
January 2000