FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
Connect electrical power to the leads in the
junction box at the rear of the machine.
Check the nameplate (located on the back panel)
for the voltage requirements, and for the minimum
circuit ampacity. The machine requires a solid
chassis to earth ground wire.
The ice machine must be connected to its own
electrical circuit so that it is individually fused.
Voltage variation must remain within design
limitations, even under starting conditions.
All external wiring must conform to national,
state, and local electrical codes. The use of a
licensed electrician is required to perform the
electrical installation.
NME1854 & FME2404
January 2000
Page 7
WATER
COOLED
AIR
COOLED
POWER
SUPPLY