beautypg.com

Initial start up – Scotsman CME855A User Manual

Page 11

background image

INITIAL START UP

Adjust for the correct size if needed:

To produce SMALLER sized ice cubes:

Locate cube size control knob in the front of the
control box. Rotate this knob one eighth of a turn
counter clockwise. Observe size of the ice cubes
in the next ice cube harvest and adjust again if
needed, until the correct ice cube is achieved.

To produce LARGER ice cubes:

Locate cube size control on the front of the control
box. Rotate the knob one eighth of a turn
clockwise. Observe size of ice cubes in the next
cube harvest and adjust again if needed, until
correct the ice cube size is achieved.

13. Check Harvest Time. The machine must
harvest all cubes before returning to a freeze cycle.

Increase the harvest time if there is less than 15
seconds of harvest time after the last cube has
fallen into the bin.

Decrease the harvest time if there is much more
than 15 seconds of harvest time after the last cube
has fallen into the bin. Note: Harvest time is
dependent upon the water and air temperatures at
the ice machine. Do not adjust harvest time too
short, as this will cause a freeze up.

See the next page for detailed harvest time
adjustment instructions.

14. Check BIN THERMOSTAT

With the ice maker in the harvest cycle, hold ice
against the metal tube of the bin thermostat
bracket. The ice machine will shut off only at the
end of the harvest cycle.

Remove the ice and within a few minutes the ice
machine should restart.

15. Replace all panels, the machine is ready for
automatic operation.

16. Fill out and mail in the Customer Evaluation
and Warranty Registration Form.

Explain to the user the specifications, operation
and maintenance requirements of the ice machine.

Inform the user of the name and telephone
number of the local service contact.

TOO

THICK

CORRECT

SIZE

CUBE

TOO

THIN

1

1

4

"

1

1

4

"

CUBES (ACTUAL SIZE)

Note: Optimum performance will be achieved when

the ice machine is adjusted to produce this size and

shape of cube. The typical batch weight at this

setting is between 8.25 and 9 pounds.

CME855A & CME1000A

October, 1994

Page 11