beautypg.com

What to do before calling for service, Reasons the machine might shut itself off, Lack of water – Scotsman CU1526 User Manual

Page 17: Freeze cycle takes too long, Harvest cycle takes too long, High discharge temperature, Push and release the off button

background image

What to do before calling for service

Reasons the machine might shut itself off:

Lack of water.

Freeze cycle takes too long.

Harvest cycle takes too long.

High discharge temperature.

Controller self test failure.

Check the following:

1. Has the water supply to the ice machine or
building been shut off? If yes, the ice machine will
automatically restart within 25 minutes after water
begins to flow to it.

2. Has power been shut off to the ice machine? If
yes, the ice machine will automatically restart when
power is restored.

3. Has someone shut the water off to a water
cooled unit? If yes, after the water supply has been
restored the ice machine may need to be manually
reset.

4. Is the curtain open because some ice is stuck
under it? If so, remove the ice and the machine
should start in a few minutes.

Note: Curtain can be removed & replaced anytime
the machine is in a standby mode or when it is in a
freeze cycle. However, removal of the curtain
during freeze will result in water flowing into the
bin. Removal of the curtain during harvest
terminates harvest at that point and, if left off, will
result in the machine shutting off.

To Manually Reset the machine.

Push and release the Off button.

Push and release the On button.

To Shut the Machine Off:

At the controller, push and hold the Off button for
3 seconds or until the machine stops.

May 2008

Page 16

CU1526, CU2026, CU3030
User Manual

Manual

Harvest

Clean

Code

Display

Component Operation Indicator Lights

Code

Description

. . . . . . . . . . Freeze Cycle

flashes . . . . Freeze Cycle is Pending

. . . . . . . . . . Harvest Cycle

flashes . . . . Manual Harvest

. . . . . . . . . . Bin is Full
. . . . . . . . . . Clean Cycle
. . . . . . . . . . Board Locked
. . . . . . . . . . Test Mode
. . . . . . . . . . Off
. . . . . . . . . . Self Test Failed

flashes. . . . Max Freeze - Retrying

. . . . . . . . . . . Max Freeze Time Shut Down

flashes . . . . Max Harvest - Retrying

. . . . . . . . . . Max Harvest Time Shut Down
. . . . . . . . . . Slow Water Fill
. . . . . . . . . . High Discharge Temp
. . . . . . . . . . Sump Temp Sensor Failure
. . . . . . . . . . Discharge Temp Sensor Failure

flashes . . . Short Freeze - Retrying

Short Freeze - Thin ice

- Unit Remotely

Locked Out - Contact Leasing Company

F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8 . . . . . . . . . . . .

All 4 Upper Lights Flashing

Control Operation - See Manual

Water Light On

De-Scale Light On

Flush Setting

Test Mode

Recall Diagnostic Codes

Reset from Code 1, 2, 4 or 8

- Restore water supply to

machine.

- Clean and sanitize

machine.

- To Change: Depress Off

for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.

- Depress Off for 3 seconds,

then depress Clean for 3 seconds.

- Depress Off

for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.

- Depress

Off then Depress On.

Technician Section

02-4302-01

On

Off

Power

Status

De-scale

Water

Sanitize

This manual is related to the following products: