Research Concepts RC3000 User Manual
Page 136

RC3000 Antenna Controller
Chapter 3
Detailed Operation
128
3.3.2.11 Configuration Item Record
Selecting the Stop/. key from the MAINTENANCE screens triggers a process that will transmit the current 
configuration item values via the remote control port. 
If the controller has the remote control option, the values will be transmitted at the baud rate set in the 
Remote configuration screen. Otherwise the default rate of 9600 baud will be used. The data will be sent 
out as 7 data bits with even parity. The data is sent out as a simple set of ASCII characters with each line 
terminated by a linefeed and carriage return. It is intended that a simple program such as HyperTerminal 
be used to pull in the data. 
The output's first three lines will contain date, time, mount type, software version number, etc. Next the 
configuration items will be sent out per configuration screen. For each configuration item, the field shown 
on the screen, the item value and the bottom row prompt associated with the item will be sent on one line. 
The following is an example output showing the first two configuration screens. 
 RC3000 CONFIGURATION ITEMS 
20OCT05 20:49:21 
V1-GTR 1.54 
 
SYSTEM DEFINITION 
 SN: 1234 SERIAL NUMBER<1-9999> (0=NOT ENTERED) 
 GPS: 1 <1>GPS PRESENT <0>NOT PRESENT 
 COMPASS: 1 <0>NONE <1>TRUCK MOUNT <2>ANTENNA MOUNT 
 MODE: 2 <1-LOCATE 2-MENU 3-MANUAL 4-VSAT 5-POS> 
 ANT_SIZE: 244 ANTENNA SIZE <1-9999 CM> 
 WAVEGUIDE: 0 WAVEGUIDE SWITCH <1>PRESENT <0>NONE 
ELEVATION CALIBRATION 
 REF_V: 1.69 SET ZERO VOLTAGE <0.50 - 4.50> 
 OFF: 0.0 ELEVATION OFFSET <-25.0/+25.0 DEGREES> 
 UP: 90 SET UP LIMIT <0-90 DEGREES> 
 DOWN: 0 SET DOWN LIMIT <0-90 DEGREES> 
 SF: 50.00 SCALE FACTOR <30.00 - 60.00 mV/deg> 
 LOOK: 1 ELEV LOOK CONFIGURATION <1>HIGH <0>LOW 
NOTE: During the time (up to 15 seconds) its takes to output all configuration item values, there will be no 
action apparent at the RC3000's front panel. The user should monitor his recording program to 
determine when the process is finished. Note also that this process will disrupt normal remote control 
actions so any other monitor and control applications should be paused during this process. 
The intent of this feature is to provide a convenient way to record configuration item values following the 
calibration of the controller. Before contacting RCI for technical support, it would also be useful to record 
the current configuration items status and send the file to RCI.