Research Concepts RC3000 User Manual
Page 109

RC3000 Antenna Controller
Chapter 3
Detailed Operation
101
If the mount is equipped with resolvers, two elevation resolver calibration items are included with the 
normal inclinometer calibration items. 
REF_V:1.69 OFF: 0.0 CONFIG-ELEV
DOWN: 0 UP: 90.0 SF:50.00
LOOK:1 RES: 0.0 REV:0
SET REFERENCE VOLTAGE <0.50 – 3.50>
RES:
ELEV RESOLVER OFFSET<+/-300.00 DEGREES>
The elev_resolver_offset configuration item defines the offset to be applied to the angle read directly from 
the elevation resolver for the purpose of displaying elevation angle. Example: If when at the elevation 
reference (deploy) position the raw elevation resolver angle reads 180.0, a elev_resolver_offset of -157.7 
will result in a resolver based elevation angle of 22.3. 
NOTE: the resolver-based angle is displayed in MANUAL mode when the elevation DOWN limit is active.
REV: ELEV
RESOLVER<0-NORMAL 1-REVERSED>
The elev_resolver_reversed configuration item defines whether the polarity of the elevation resolver 
matches that of the RC3000 resolver circuitry. If the raw elevation resolver angle decreases as the 
mount moves up, the elev_resolver_reversed item must be described as reversed. 
