7 electrical configuration - i/0 module 01, Remko wkf duo, Electrical configuration - i/0 module 01 – REMKO WKF-120-180Duo Electrical wiring User Manual

Page 16: Smt i/0 01

background image

2.7

Electrical configuration - I/0 module 01

Use wire gauge corresponding with the connection cable supplied!

Lay load lines separately to measuring lines!

2nd mixed heating cycle

Mixing valve 230 V

Closed

Open

Closed

Open

Closed

Open

Bypass valve

Indoor unit 230 V

1st mixed heating cycle

Mixing valve 230 V

Circulation pump
Hot water 230 V

Unmixed heating cycle

Pump 230 V (optional)

1st mixed heating cycle

Pump 230 V

Pump solar 230 V

unregulated

Changeover valve

Pump, cooling

Pump 230 V

2nd mixed heating cycle

Not assigned

Changeover valve

2. Heat generator (BVT)

Changeover valve

Hot water preparation

Power supply

230 V

Power supply

Internal pump - indoor unit

Power supply I/0 module

Communication

Outdoor unit

2 x 1.5 mm2

Power supply

Indoor unit

3 x 1.5 mm2

T

erminal block X1.1

Assigned

Assigned

Assigned

Assigned

Assigned

Assigned

Assigned

Assigned

Assigned

Mains voltage connection provided by

the customer (bauseitig) from sub-distribution!

Mains voltage connection provided by the customer (bauseitig) from sub-distribution!

Outdoor unit

WKF 120 / WKF 120 Duo

230V/1~/N/Pe

E.g. 3 x 2.5 mm2

Outdoor unit

WKF 180 / WKF 180 Duo

400V/3~/N/Pe

E.g. 5 x 1.5 mm2

Electric heating coil 9kW

Mains voltage

400V/3~/N/Pe

E.g. 5 x 2.5 mm2

Plug on the heating coil

Potential-free

A34.1 General
alarm signal
A33.1 no
function
A32.1 enable

2. WE Smart BVT/Serv

A31.1 no
function
A30.1 no
function

Refrigerant

A24/25.1

S07.1

Solar
return flow

S04.1

Solar storage tank, bottom

S02.1

Solar collector

S01.1

Medium flow rate HP

S24.1

Medium flow rate solar

S23.1

Not connected

A22/23.1

A20/21.1

A04.1

A03.1

A02.1

A01.1

A14.1

A13.1

A12.1

A11.1

A10.1

NOTE: without blocking contactor,
jumper must be inserted
Closed = enable

Energy supply provider contact

S16.1

Heat pump RF

S15.1

2nd mixed heating cycle RF S14.1

Coding resistor

RC.1

Heat pump inlet

S13.1

Communication Com-Kit 1 B2/A2

1st mixed heating cycle RF

S11.1

1st mixed Heating cycle inlet

S12.1

Operating module SMT 1 B1/A1

Outside temperature S10.1

Storage tank, centre S09.1

Hot water probe

S08.1

2nd mixed Heating cycle inlet

S06.1

Pump 0-10V

A46.1

2nd mixed Heating cycle

Circulation

S05.1

Temperature or impulse

Solar probe inlet

S03.1

Pump 0-10V (indoor unit)

A43.1

Pump 0-10V (HGU)

A42.1

Unmixed Heating cycle

Pump 0-10V (HGM)

A41.1

1st mixed Heating cycle

Speed setting PWM

A40.1

Solar pump

S29.1/GND

S28.1/GND

S27.1/GND

S26.1/GND

S25.1/GND

S0 PV feed-in
(min. 500 lmp./kWh)

S0 PV yield
(min. 500 lmp./kWh)

S0 household meter
(min. 500 lmp./kWh)

S0 HP electricity meter
(min. 500 lmp./kWh)

Not connected

SMT I/0 01

REMKO WKF Duo